SV 300 B - ATEX Click image to view full size
Item-Name:

SV 300 B - ATEX

Specification:

Technical Data

SOGEVAC SV 300 B

50 Hz

60 Hz

Nominal speed 1)    m3 . h-1

280

340 (200)

Pumping speed 1   m3 . h-1

240

290

Ultimate partial pressure without gas ballast 1) mbar

≤ 8.10-2

≤ 8.10-2

Ultimate total pressure with small gas ballast 4Nm3/h     mbar                 

≤ 0.5

≤ 0.5

Ultimate total pressure with standard gas ballast 7.5 Nm3/h also for EM gas ballast 10   Nm3/h     mbar

≤ 0.7

≤ 0.7

Ultimate total pressure with big gas ballast 15 Nm3/h     mbar

≤ 2,0

≤ 2,0

Ultimate total pressure with two big gas ballasts 28 Nm3/h       mbar

≤ 3,0

≤ 3,0

Water vapour tolerance with small gas ballast 4 Nm3/h            mbar

4
with turbine 220 mm

5
with turbine 220 mm

Water vapour capacity with small gas ballast 4 Nm3/h         kg.h-1

0.4
with turbine 220 mm

0.6
with turbine 220 mm

 Water vapour tolerance with standard gas ballast 7.5 Nm3/h
also for EM gas ballast 10 Nm3/h

 

mbar

10
with turbine 220 mm

12
with turbine 220 mm

40
with turbine 150 mm

50
with turbine 150 mm

Water vapour capacity with standard gas ballast 7.5 Nm3/h
also for EM gas ballast 10 Nm3/h

 

 

kg.h-1

 

1,3
with turbine 220 mm

 

1,8
with turbine 220 mm

6,0
with turbine 150 mm

8,0
with turbine 150 mm

Water vapour tolerance with big gas ballast 15 Nm3/h                   mbar

70
with turbine 150 mm

70
with turbine 150 mm

Water vapour capacity with big gas ballast 15 Nm3/h                    kg.h-1

11
with turbine 150 mm

14
with turbine 150 mm

Water vapour tolerance with two big gas ballasts 28 Nm3/h               mbar

95
with turbine 150 mm

95
with turbine 150 mm

Water vapour capacity with two big gas ballasts 28 Nm3/h                kg.h-1

15
with turbine 150 mm

17
with turbine 150 mm

Noise level 2)      dB(A)

72

76

Leak rate    mbar . l x.s-1

≤ 1.10-3

≤ 1.10-3

Mains voltage (std) - for other voltages please contact Oerlikon Leybold Vacuum

V

See Ordering data

Motor power  kW

See Ordering data

Type of protection

IP55

IP55

Rated rotational speed     min.-1

1450

1750

Weight (with oilfilling)   kg

200

200

Oil capacity (min. / max.)     l

8,5/11,5

8,5/11,5)

Intake connection

G2

G2 NPT2 3)nN

Exhaust connection

G2

G2 NPT2 3)

  1. according to DIN28400 and following numbers, with standard gas ballast
    2. operated at ultimate pressure without gas ballast, free-field measurements at a distance of 1m
    3. please contact Oerlikon Leybold Vacuum