GXS450F Click image to view full size
Item-Name:

GXS450F

Specification:

 
 

Units

GXS450F

Peak Pumping Speed

m3h-1 (cfm)

450 (265)

Ultimate Pressure (without purge)

mbar (Torr)

5x10-3 (3.8x10-3)

Full Load Power

@ ultimate pressure

kW (hp)

7.2 (9.6)

@ peak pumping load

kW (hp)

17.3 (23.2)

Electrical

Supply options

High volt

380-460V 3Ø 50/60Hz

Low volt

200-230V 3Ø 50/60Hz

Connection

High volt

Harting Han K 4/4-F

Low volt

 

Vacuum Couplings

Inlet

ISO100

Exhaust

NW50

Cooling Water

Supply pressure (max)

bar (psig)

6.9 (100)

DP across pump (min)

bar (psig)

1 (15)

Flow @ min DP

lmin-1 (gal/min)

6 (1.6)

Temperature

°C (°F)

5-40 (41-104) All variants

Connection

1/2" BSP Male (R 1/2”)

Purge Gas*

Pressure

bar (psig)

2.5-6.9 (36-100)

Light Duty

sl/min

12

Medium Duty

sl/min

18-146

Connection

Swagelok® Ø ¼” tube with olive

High Flow Purge/ Solvent Flush

Supply pressure

bar (psig)

2.5-6.9 (36-100)

Control valve connection

Swagelok® Ø 3/8" tube with olive

Filter connection

½" NPT Female

Solvent connection

3/8" BSP Male (G 3/8")

Mass

kg (lbs)

640 (1411)

Noise (with suitable exhaust pipe)

dB(A)

<64

Operating Temperature

°C (°F)

5-40 (41-104)

Exhaust Back Pressure (MAX)

mbar (psia)

1400 (20)

System IP rating

Standard

31

Lubrication

Type

PFPE Drynert® 25/6

Volume

l (gal)

1.8 (0.5)

Monitoring &
Control
 
 
 
 
 

Standard

Control

Front panel "Dashboard"

Serial - RS232

Monitoring

Ethernet Webserver

Option

Control

Parallel - MCM MicroTIM

Control & Monitoring

Profibus DP

Pump Display Terminal (PDT)

Monitoring

FabWorks®

*Pump combinations

Light duty

Shaft Seal Purge & High Vac Purge only

 
 

Medium duty

Shaft Seal Purge, High Vac Purge, Inlet Purge, variable Gas Ballast & Exhaust Purge (with Exhaust Pressure Sensor)

 
 

Medium duty +

As Medium duty, plus High Flow Purge / Solvent Flush

 

* Purge Gas information
Light duty: shaft seal purge only
Medium duty: Shaft seal purge, inlet purge, variable gas ballast & exhaust purge (with exhaust pressure sensor)
Medium duty plus: As Medium duty, plus High Flow Purge / Solvent Flush